Before seeking repair or replacement, we recommend that
you review the following:
SAFETY NOTE: Before investigating you must disconnect the
power supply. Depending on the installation this can be done by
either removing the plug from the socket or for continuous feed
models, switching the disposer control to OFF.
LOUD NOISES: (Other than those during grinding of bones
and fruit pits) These are usually caused by accidental entry of a
spoon, bottle cap or other foreign object. To correct this, remove
*splash guard and remove object with long handled tongs.
Replace *splash guard.
UNIT DOES NOT START: With *splash guard removed, check
to see if turntable will rotate freely using a wooden utensil.
If turntable rotates freely, replace *splash guard and check reset
button to see if it has been tripped. Reset button is red and
located opposite discharge elbow, near the bottom (see 8A).
Push button in until it clicks and remains depressed.
If reset button has not been tripped, check for shorted or broken
wire connecting to disposer. Check electrical power switch, fuse
box or circuit breaker. If wiring and electrical components are
intact, the unit may have internal problems that require service or
replacement.
IF TURNTABLE DOES NOT ROTATE FREELY: Check for foreign
object lodged between the turntable and grind ring. Dislodge
object by rotating table with a wooden utensil and remove
object (see 8B). If no foreign object is present, there may be
internal problems.
CONNECTION OF AIR SWITCH TO UNIT: To connect the air
switch the tube should be connect to the nipple on the underside
of the unit by pushing it on firmly.
LEAKS: If the unit leaks at the top, it may be due to:
1. Improper seating of sink flange (gasket choice, putty
or tightening.)
2. Support ring not tightened properly.
3. Defective cushion mount.
If unit leaks at the waste elbow, leak may be due to improper
tightening of elbow flange screws.
WARNING: Before resetting, disconnect the power supply -
please see SAFETY NOTE above. The overload control prevents
the motor from operating should overloading occur. This safety
feature protects your house wiring and your disposer. When
overloaded, the motor will stop automatically.
*Splash guard is not used with Batch Feed or 3-Bolt Mount units.
8. TROUBLESHOOTING
7A
RESET
BUTTON
SERIAL NO.
8A
REMOVE
SPLASH GUARD
TURNTABLE
8B
Vista de pagina 7